Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guida All'Installazione

Pagina di 282
 
 
Optical Switch Module 
OL-29643-02 
61 
 
 
Primary Input 
Secondary Input 
Alarms 
Optical Switch 
Path A Optical Power > 
ThresholdA (default) 
Path B Optical Power > 
Threshold B [1] 
None 
Switch to Path A 
Path A Optical Power < 
ThresholdA (default) 
Path B Optical Power > 
Threshold B [1] 
Loss of Input 
Light at Path A 
Switch to Path B 
Optical Power 
Path B Optical Power > 
Threshold B [1] 
Path B Optical Power < 
Threshold B [1] 
Loss of Input 
Light at Path B 
Switch to Path A 
Path A Optical Power < 
ThresholdA (default) 
Path B Optical Power < 
Threshold B [1] 
Both Dark 
Switch to Path A 
Optical Power 
Path B Optical Power > 
ThresholdB (User 
Setting) 
Path A Optical Power > 
ThresholdA [1] 
None 
Switch to Path B 
Path B Optical Power < 
ThresholdB (User 
Setting) 
Path A Optical Power > 
ThresholdA [1] 
Loss of Input 
Light at Path B 
Switch to Path A 
Optical Power   
Path B Optical Power > 
ThresholdB (User 
Setting) 
Path A Optical Power < 
ThresholdA [1] 
Loss of Input 
Light at Path A 
Switch to Path B 
Path B Optical Power < 
ThresholdB (User 
Setting) 
Path A Optical Power < 
ThresholdA [1] 
Both Dark 
Switch to Path B 
Optical Power   
[1] Hysteresis Amplitude (default 1.0 dB) is the value above which the input optical 
power must rise for the switch to begin sequence to return to the primary switch 
position. Hysteresis Amplitude is a user configurable parameter. 
Configurable Parameters 
The following table defines the configurable parameters for the optical switch. 
 
Parameter Function 
Default 
Value 
Values Min 
Max 
Step 
Unit 
Mode Automatic 
or 
manual mode 
Auto(0) Auto(0) 
Manual(1)
 
 
 
 
Threshold 
B  
Switching 
threshold, input 
optical power at 
input B 
5.0  
-10.0 
14.0 
0.1 
dBm
Threshold 
Switching 
threshold, input 
optical power at 
input A 
5.0  
-10.0 
14.0 
0.1 
dBm