Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guida All'Installazione

Pagina di 192
 
Appendix B 
Enhanced Digital Return Multiplexing Applications 
126 
 
Transmitter Module Setup Procedure 
Perform the following steps to set up the reverse transmitter module(s). 
1  Open the housing according to Opening and Closing the Housing (on page 68). 
2  Verify the level of the reverse path RF signal at the RF test points on the RF 
module. Nominal level is +15 dBmV per channel. Install the appropriate value 
input pad at the REV PORT IN PAD location to give the desired signal level into 
the node. 
3  Repeat step 3 for each RF cable carrying a reverse path signal. 
4  Measure the transmitter module(s) optical output power. 
5  Check the connection of the optical connector. Make sure the optical connector is 
seated and verify fiber bend radius is greater than 1 inch. 
 
    WARNING: 
When handling optical fibers always follow laser safety precautions. 
EDR Transmitter Status Indicators 
The transmitter module has two status indicator LEDs. 
The following section describes the LED status and the correspondent indications. 
The input level overdrive indicates the input signal level exceeds the limit of 35 
dBmV. 
For EDR 1:1 transmitter module 
The following table lists the LED status and the indicated OPM, and the overdrive 
status of the RF port.   
LED 
Indication 
Power (PWR)  Laser (LSR) 
OPM Module 
Port Input Overdrive 
OFF 
OFF 
Green 
Green 
Cisco Standard OPM Module 
No 
Green 
Orange 
(Solid) 
Non-Cisco Standard OPM 
Module 
No 
Green 
Orange 
(Blink) 
Cisco Standard OPM Module/ 
Non-Cisco Standard OPM 
Module 
Yes