Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guida All'Installazione

Pagina di 192
 
Appendix B 
Enhanced Digital Return Multiplexing Applications 
134 
 
Orange 
(Blink) 
Orange 
(Blink) 
Non-Cisco Standard OPM 
Module is in use. 
Input Level Overdrive. 
Verify the input level of RF port 1.   
The output level overdrive 
indicates the output signal level 
exceeds the limit of 35 dBmV. 
Verify the input level of RF port 1.   
The output level overdrive 
indicates the output signal level 
exceeds the limit of 35 dBmV. 
Cisco Standard OPM Module is 
highly recommended for better 
system performance and stability. 
See the data sheet of the node for 
ordering information. 
 
Follow the steps in the table below to troubleshoot the transmitter module. 
Symptom 
Possible Cause 
Possible Solutions 
No optical signal output 
Laser temperature could be 
too high or low. 
Allow up to one minute after 
power is ON for the 
temperature to stabilize. 
If still no output, contact the 
Cisco Technical Service Center 
for assistance. 
Laser could be faulty. 
Contact the Cisco Technical 
Service Center for assistance. 
Automatic power control 
circuit failure. 
Contact the Cisco Technical 
Service Center for assistance. 
 
Damaged fiber. 
Contact the Cisco Technical 
Service Center for assistance. 
 
Symptom 
Possible Cause 
Possible Solutions 
No optical signal output 
(cont'd) 
One or more power supply 
voltages are out of 
specification. 
Check the power supply for 
proper operation. 
No AC at receptacle. 
Check the receptacle for AC 
power. 
Blown fuse on the power 
supply. 
Check the power supply fuse 
and replace as necessary.