Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Guida All'Installazione
Status Monitor Configuration Procedure
4024769 Rev A
27
Menu Item Configuration Parameter Description/Values
3
3
RX FREQUENCY
Description: The downstream frequency on
which the transponder receives commands from
the headend.
which the transponder receives commands from
the headend.
Value: xxx.xx MHz
4
TX FREQUENCY
Description: The upstream frequency on which
the transponder transmits to the headend.
the transponder transmits to the headend.
Value: xxx.xx MHz
Note: This menu item does not display following
discovery by the headend modem termination
system (HMTS).
discovery by the headend modem termination
system (HMTS).
5
FREQUENCY SCAN
Description: Set transponder to auto-scan for
communications frequency with the headend.
communications frequency with the headend.
Values: Yes, No
Note: This menu item does not display following
discovery by the HMTS.
discovery by the HMTS.
6
TX LEVEL
Description: The transponder's transmitting
output power level.
output power level.
Values: Valid range is 24 dBmV to 50 dBmV
7
RX LEVEL
Description: The transponder's receive power
level.
level.
Values: Operational range is -20 dBmV to +20
dBmV (Anything over +30 dBmV can cause
equipment damage.)
dBmV (Anything over +30 dBmV can cause
equipment damage.)
8
STATUS
Description: Transponder module status.
Values: No Freq Found, Registered, Ch
Description
Description