Cisco Headend System Release 2.7 Guida All'Installazione
![Cisco](https://files.manualsbrain.com/attachments/7380d0050044647c30f5c24bbbf5d0c0b6d9bb84/common/fit/150/50/faa183d287233c52228cfea3dbc2a127fe780f60564fcb0955d9c3d1cd23/brand_logo.png)
Chapter 3 Setting Up Hubs, MPEG Sources, MQAM Modulators, PCGs, and SCSs
50
4017650 Rev C
3 Click New. The New PowerKEY CAS Gateway window opens.
4 Click in the Name field and type the name of this PCG. You can use up to 20
alphanumeric characters without spaces between the characters.
Important: We recommend that you establish a naming scheme that allows you
to easily identify the PCG and where it resides.
Example: A name of PCG12 could represent a PCG, whose IP address ends in 12.
Important: We recommend that you establish a naming scheme that allows you
to easily identify the PCG and where it resides.
Example: A name of PCG12 could represent a PCG, whose IP address ends in 12.
5 Click in the Control NIC IP Address field and type the IP address for this PCG.
Be careful to properly place the dots (.) between numbers.
6 Click in the Subnet Mask field and type the subnet mask where the PCG resides
(for the above NIC IP address), based on the following guidelines:
If your system uses a standard network configuration, type 255.255.255.0.
If your system uses another type of network configuration, type the subnet
mask as assigned by your system administrator.
mask as assigned by your system administrator.
7 Click the Control NIC MAC Address field and type the MAC address for this
NIC on the PCG. Be careful to properly place the colon (:) between the numbers.
8 Click the Default Gateway field and type the default gateway IP for the above
NIC IP address. Be careful to properly place the dots (.) between the numbers.
9 Click the Max Sessions field and type the maximum sessions allowed on the
PCG. This is any integer value between 1 and 1000.
10 Click the Enabled check box to activate the PCG.
11 Click the DNCS=>PCG Msg Timeout field and type any integer value between
11 Click the DNCS=>PCG Msg Timeout field and type any integer value between
5 and 60.
12 Click the PCG=>SCS Timeout field and type any integer value between 5 and
60.
13 Click the CW_Provision Msg Repetition Rate field and type 1.
14 Click the ID field and type any integer value which uniquely identifies this PCG.
15 Click the Config File field and type the config file name used to send to the PCG
14 Click the ID field and type any integer value which uniquely identifies this PCG.
15 Click the Config File field and type the config file name used to send to the PCG
(For example, pcg.config).