Cisco Headend Digital Broadband Delivery System Guida Utente
Chapter 2 Staging the Tuning Adapter
18
4025012 Rev B
Verify the PowerKEY Information
You can verify the staged PowerKEY information using the diagnostic screen on the
UDCP device to which the Tuning Adapter is connected.
1 Connect the Tuning Adapter to a UDCP device that is connected to a TV.
2 Access the diagnostic screens using the instructions supplied with your UDCP
2 Access the diagnostic screens using the instructions supplied with your UDCP
device.
3 Go to the Network and Tuning Status page of the diagnostic screens.
4 Verify that the ENTITLEMENT AGENTS / ISE(1): field displays 0x0000001.
5 Verify the EMMs: / ISE: field displays the same number of EMMs that the UDCP
4 Verify that the ENTITLEMENT AGENTS / ISE(1): field displays 0x0000001.
5 Verify the EMMs: / ISE: field displays the same number of EMMs that the UDCP
device requires.
6 Verify that the Sub Expires field displays the appropriate time stamp (usually 30
days in the future).
Notes:
Notes:
The EMMs: / ISE field will vary based on the level of Service Authorizations
provisioned for the UDCP device.
When the Tuning Adapter has received all its PowerKEY information, the
Time GBAMs: / ISE field will increment, and the ISE error count will no
longer increase.
Refer to Understanding Diagnostic Screens for the Tuning Adapter (part number
4025082) for more information.
Results:
The Entitlement Agent displays ISE (1) 0X000000001
The Sub Expire date is set to 30 days from today
7 Do the pages display all of the items shown in the results of the preceding step?
If yes, go to step 8.
If no, send an instant hit to the Tuning Adapter using one of the following
methods:
–
–
Using the billing system. The billing system has been set up to send the
DhctInstantHit command to Tuning Adapters. Refer to your billing
system documentation for instructions and specific information.
–
Using the DNCS. See
Send Instant Hits (on page 29) for more
information.
8 Did the instant hit increase the EMM count to the required number?
If yes, you are finished with this procedure.