Post-Install Checklist 
  Ensure that there are symlinks so that Tomcat will restart if the system is 
rebooted.  
  If you are using phone control, verify that the phones work. 
  Verify that channel names and favorites are properly set.  
  Verify that all devices are properly in the nonevent_group .  
  Verify that log4j.properties is set to INFO.  
  Verify log rotation for catalina.out is in place  
  Verify a cron tab is in place to purge logging files after 60 or 90 days.  
  Verify that the http://host:8080/StadiumVision/diagnostics/ looks clean on the 
server.  
  Upgrade only: Verify that the tools.js has been run manually if it did not succeed 
automatically and/or you are upgrading the database ahead of time.  
  Enable localhost_access_log by editing /opt/apache-tomcat.../conf/server.xml. To 
do this, look for the section which looks like this:  
<!-- Access log processes all example. 
Documentation at: /docs/config/valve.html --> 
<!-- 
<Valve 
className="org.apache.catalina.valves.AccessLogValve" 
directory="logs" 
prefix="localhost_access_log." suffix=".txt" 
pattern="common" resolveHosts="false"/> 
--> 
and then make sure to uncomment the section that has  
<Valve 
className="org.apache.catalina.valves.AccessLogValve" 
directory="logs" 
  Verify that the Control Panel UI shows the expected SVD version and build 
number. For example v2.3.0 Build 78. 
  Check the Services Alert window in the Management Dashboard and make sure 
that all relevant services are showing green. 
  Check that all DMPs and TVs in the Management Dashboard are showing green. 
  Start an existing event script and validate that screens display the expected 
content. 
  Stop the event script and validate that screens are powered off. 
  Make a minor edit to the event script and make sure it can be saved. 
  Verify that VDM can push a new video file to the DMPs. 
  Perform a DB backup and restore. 
  Failover the primary SVD to the secondary SVD. 
  Run through the failover procedure.