the power supply shuts down or latches off, a cycle of off for 15 seconds and on 
for 1 second will reset the power supply. 
Over-current Protection (OCP) 
The power supply shuts down and latches off after an over-current condition 
occurs. This latch is cleared by a power interruption. 
The power supply will not be damaged from power cycling. 
Over-voltage Protection (OVP) 
The power supply shuts down and latches off after an overvoltage condition 
occurs. This latch is cleared by a power interruption. 
Over-temperature Protection (OTP) 
The power supply is protected against over-temperature conditions caused by 
the loss of fan cooling or excessive ambient temperature. In an OTP condition, 
the power supply will shut down. When the power supply temperature drops to 
the rated safety limit, the power supply restores power automatically. 
Regulatory Compliance 
For regulatory compliance and safety information, see the Cisco Regulatory 
Compliance and Safety Information for the Cisco Application Deployment Engine 