Symptom: Local PNGs are not synchronized across SV-4K and
DMP-2K devices
Troubleshooting steps:
1. Verify the PTP configuration on your SV-4K and DMP-2K devices:
a. Go to:
Management Dashboard SV Director Configuration Global DMP
Settings SV-DMP Common Settings
b. Verify that the PTP domain and PTP master candidates property configuration
is correct for your network.
2. Open your browser and navigate to one of the devices:
http://sv4k-ip-address/ptp.html
3. Enter the username and password.
4. Look for the message “PTP is not enabled.”
This message might mean that the device was not rebooted after changes to the
Management Dashboard settings.
5. If the message appears, reboot the SV-4K or DMP-2K device.
Symptom: Playlists do not advance to the next content item on
the SV-4K or DMP-2K
If the current PTP master becomes unreachable (shuts down, or becomes unreachable
on the network), the PTP members will be unable to update their clocks and this
condition will occur.
Troubleshooting steps:
1. Verify the PTP configuration on your SV-4K or DMP-2K devices:
a. Go to:
Management Dashboard SV Director Configuration Global DMP
Settings SV-DMP Common Settings