9.  Power the DMP of by pushing the power switch. Leave it off for a minute and 
then power it back on. Restart video play out from the DMPDM and verify 
that it plays out with the expected quality. 
10. Subject both DMP and TV to burn in by letting the video play uninterrupted 
for 12 hours straight. Then repeat steps 8 and 9. 
RS-232 
This section describes how to validate the RS-232 cable and control codes. 
1.  Determine and record the RS-232 control codes for the TV under 
qualification. These can typically be found in the user manual for the TV in 
question. See 
 
for an example. Record the subset of codes needed by Cisco 
StadiumVision Director in 
 below. 
2.  Connect the DB9 to DB9 RS-232 cable between laptop and TV. If the TVs 
RS-232 connector is the wrong gender then insert the DB9 null modem 
adaptor. If the TVs RS-232 connector is not DB9 then create a custom 
cable to match. 
3.  Use Hyperterm, Putty or some other terminal emulator SW to manually 
send the RS-232 ‘Power ON’ control code to the TV. If the TV does not 
power on then trouble shoot the cable pin-out and reconfirm the RS-232 
command code. 
4.  Validate that the TVs response to the RS-232 Power ON command 
matches what is recorded i
 for Power On Confirm. 
5.  Manually transmit the remaining RS-232 controls codes from 
 and 
confirm that the TV reacts as expected. 
6.  Change the RS-232 cabling so the DMP connects to the TV instead of the 
laptop. 
7.  From the laptop browse to the IP address of the DMP. From the DMPDM 
navigate to the ‘Serial Interface’ tab and paste the RS-232 Power ON 
control code into the ‘Hex String’ field. Click ‘Send Message’ to transmit 
the command to the TV. If the TV does not power on as a result then the 
cable pin-out is possibly incorrect.  
8.  If qualification determines that a custom RS-232 cable is needed then 
have these ordered ASAP so they can be available when DMP 
deployment starts.