Cisco Cisco StadiumVision Director Manuale Di Manutenzione

Pagina di 103
 
 
© 2011 Cisco Systems, Inc. All rights reserved.   
 
Page 66 of 103 
4.  The dmp.RelativeVolumeSteps will automatically be selected in the available list 
Click << to add it to the configured list.  
5.  Select the dmp.RelativeVolumeSteps command in the configured list and click + 
at the upper right of the Serial Strings of Selected Commands. Enter the 
appropriate value for the steps (as described above). 
6.  Press Enter. 
7.  Click Save
Setting a Delay Between Repeated Serial Commands 
Some models of TVs discard repeated serial commands that are sent too close 
together. For those TVs, you can add and define a serial command with the label 
“dmp.SerialDelay.” The value that you specify for dmp.SerialDelay represents the 
delay between sending repeated serial commands from the DMP. By default, the 
value is 5000 (milliseconds). If the value is set lower, the delay between messages 
is decreased. Note that dmp.SerialDelay does not impact the rate at which other 
RS-232 commands are sent when more than one command is lined up for 
transmission. 
To define the delay between repeated serial commands: 
1.  On the Serial Commands tab for the desired TV type, click the + at the upper 
right of the Available Serial Commands list box. 
2.  Click + at the upper right of the Available Serial Commands box and add a 
corresponding command called dmp.SerialDelay. 
3.  Press Enter. 
4.  The dmp.SerialDelay will automatically be selected in the available list. Click << 
to add it to the configured list. 
5.  Select the dmp.SerialDelay command in the configured list and click + at the 
upper right of the Serial Strings of Selected Commands. Enter the appropriate 
value for the steps (as described above). 
6.  Press Enter. 
7.  Click Save
Defining Input Commands 
Most TV types have multiple inputs available. For TVs in public areas, such as 
concourses, it is likely that only one of these inputs will be used. However, in areas 
with local TV control (such as clubs, back offices, locker rooms, and luxury suites), 
additional inputs may be used to provide connectivity to DVD players, PCs, etc. You 
can define labels and serial commands to control the use of these inputs.