Cisco Cisco StadiumVision Director Manuale Di Manutenzione

Pagina di 40
 
 
© 2011 Cisco Systems, Inc. All rights reserved.
 
 
Page 38 of 40 
 
Table 5. 
CLI Commands sent by the Dashboard 
Command  
CLI Commands Sent to Switch sjc_29_lab_gw1  
Power Cycle DMP interface 
Gi2/17 
shutdown 
no shutdown 
Run cabling Test 
using TDR test cable-diagnostics TDR interface Gi2/17  
Show TDR Test Results 
show cable-diagnostics TDR interface Gi2/17  
Ping Test ping 
10.10.1.1  
Clear ARP Cache 
clear arp-cache interface Gi2/17  
Power Cycling a DMP 
Send the Power Cycle DMP switch command to cycle PoE (Power over Ethernet) on 
the switch port to which the DMP is connected. This will reboot the DMP. The DMP 
power cycle uses PoE and sends the shut CLI command to the appropriate switch / 
port based on selected DMP(s). 
 
DMP 4305Gs require a special adapter to enable them to properly process 
the PoE command. 
Power On/Power Off  the DMP 
Send the Power On or Power Off command to turn the power on or off on the 
selected DMP(s). These commands use Power over Ethernet and send the shut CLI 
command to the appropriate Switch / port based on selected DMP(s). 
Running a Cable Test Using TDR 
Send the Run Cable Test Using TDR switch command to invoke a Time Domain 
Reflectometer (TDR) test for a specific switch port. This test helps you to confirm the 
integrity of the port and cable connection to the DMP. Suitable CLI is sent to the 
switch to which the DMP is connected. 
Showing TDR Test Results 
Send the Show TDR Test Results switch command to display the results of the 
previously executed TDR Test command. 
Sending a Ping from the Switch to the DMP 
Send the Ping Test switch command to send a ping to a DMP from the switch to 
which it is directly connected. The output from the switch as a result of the ping test is 
displayed on the Console tab below the DMP Details window.