Cisco Cisco StadiumVision Director

Pagina di 60
32
Release Notes for Cisco StadiumVision Director Release 4.0
 
  Installation Notes
The Cisco StadiumVision Director Remote software is installed on the customer’s choice of 
hardware that supports a VMware virtualized environment, or the remote server hardware is 
installed in a data center or in an enterprise data closet.
Installation Requirements on New Platform 3 Servers
Caution
New Platform 3 servers (SV-DIR-DIRECTOR-K9 and SV-PLATFORM3=) come pre-installed with a 
preliminary image of Cisco StadiumVision Director that is not intended for production operation. You 
must install the Cisco StadiumVision Director Release 4.0 software from a full ISO image (not an 
upgrade) that you downloaded from Cisco.com to be sure that you are running the released production 
version of Cisco StadiumVision Director Release 4.0. 
For information about installing a fresh ISO image on a Platform 3 server, see the 
.
Cisco StadiumVision Director Remote OVF Deployment
New installations of the Cisco StadiumVision Director Remote Release 4.0.0-66 software are deployed 
using an Open Virtualization Format (OVF) template and installing a full ISO. 
For more information about installation files and upgrade paths, see the 
.
For more information about installing Cisco StadiumVision Director Remote, see the 
.
CIMC and BIOS Firmware Installation for Cisco StadiumVision Director 
Platform 2 Servers
Platform 2 (SV-DIRECTOR-K9 or SV-PLATFORM2=) of the Cisco StadiumVision Director server 
requires installation of the Unified Computing System (UCS) Server Firmware Version 1.4(2) or later to 
avoid problems powering off the server hardware.
Verifying the BIOS Firmware Version
You can verify the firmware version installed on Platform 2 of the Cisco StadiumVision Director server 
by running a Basic System State Report from the Cisco StadiumVision Director main menu.
Note
BIOS firmware version 1.4.1 is the compatible version packaged with CIMC firmware version 1.4.2.
In the OS Information section of the Basic System State Report, look for “BIOS Information” and 
“Version” below the “Handle 0x00005, DMI type 0, 24 bytes” line, as shown in the following example.
If your version is less than “1.4.1,” then an upgrade is needed:
Handle 0x0005, DMI type 0, 24 bytes.
BIOS Information
Vendor: Cisco Systems, Inc.