GainMaker Amplifier Reverse Switch Removal Instruction Sheet
13
System Amplifier Reverse Switch Removal,
Continued
Closing the System Amplifier Housing
Follow these steps to close the system amplifier housing.
1.
Inspect the housing gasket and all mating surfaces. Wipe off any dirt and
debris.
CAUTION:
Avoid moisture damage and RF leakage! Follow steps 2 and 3
exactly as
explained below to ensure a proper seal.
2.
Close the housing and finger-tighten all closure bolts.
3.
Using a torque wrench, tighten each closure bolt from 5 ft-lb to 12 ft-lb (6.8
Nm to 16.3 Nm).
Important: Follow the numbered sequence shown below to tighten the bolts.
Important: Follow the numbered sequence shown below to tighten the bolts.
4.
Is the system amplifier located in the field?
•
•
If Yes, the reverse switch removal procedure is complete.
•
If No, proceed to Re-Boxing the System Amplifier.
Re-Boxing the System Amplifier
Follow these steps to re-box the system amplifier.
1.
Put the system amplifier back into its original box, then seal the box.
2.
Place the new 3”x 2” label over the original label on the side of the box.