Cisco Cisco Legacy Line Extenders Scheda Tecnica
Station Powering Data
Line Extender III PHD
I
DC
AC Voltage
(Amps)
90
85
80
75
70
65
60
55
50
45
40
35
Manual / Thermal AC Current (A)
0.76
0.38
0.41
0.42 0.44
0.46 0.48 0.49
0.52
0.55 0.58
0.61
0.67
Power (W)
22.2
21.8
21.8 21.9
21.5 21.8 21.8
21.7
22.3 22.3
21.8
22.2
AGC
AC Current (A)
0.86
0.42
0.46
0.46 0.48
0.50 0.52 0.54
0.57
0.60 0.64
0.68
0.76
Power (W)
24.7
24.4
24.3 24.4
24.2 24.3 24.4
24.3
24.8 24.8
24.4
24.6
Scientific-Atlanta, Inc.
http://www.sciatl.com
United States: 4261 Communications Drive, P.O. Box 6850, Norcross, GA 30091-6850; Tel: 800-433-6222; Fax: 770-903-4617
Canada: 7725 Lougheed Highway, Burnaby, BC V5A 4V8; Tel: 604-420-5322; Fax: 604-420-5941
United Kingdom: Home Park Estate, Kings Langley, Herts WD4 8LZ, England; Tel: 44-923-266-133; Fax: 44-192-327-0448
Australia: Unit 2, 2 Aquatic Drive, P.O. Box 292, Frenchs Forest, NSW 2086, Australia; Tel: 61-2-9452-3388; Fax: 61-2-9451-4432
Singapore: 1 Claymore Drive, #08-11 Orchard Towers, Singapore 229594; Tel: 65-733-4314; Fax: 65-733-2706
Hong Kong: Suite 56 & 57, 5/F New Henry House, 10 Ice House Street, Central, Hong Kong; Tel: 852-2522-5059; Fax: 852-2522-5624
Canada: 7725 Lougheed Highway, Burnaby, BC V5A 4V8; Tel: 604-420-5322; Fax: 604-420-5941
United Kingdom: Home Park Estate, Kings Langley, Herts WD4 8LZ, England; Tel: 44-923-266-133; Fax: 44-192-327-0448
Australia: Unit 2, 2 Aquatic Drive, P.O. Box 292, Frenchs Forest, NSW 2086, Australia; Tel: 61-2-9452-3388; Fax: 61-2-9451-4432
Singapore: 1 Claymore Drive, #08-11 Orchard Towers, Singapore 229594; Tel: 65-733-4314; Fax: 65-733-2706
Hong Kong: Suite 56 & 57, 5/F New Henry House, 10 Ice House Street, Central, Hong Kong; Tel: 852-2522-5059; Fax: 852-2522-5624
P/N 587991 Rev A
© 1998 Scientific-Atlanta, Inc.
All rights reserved.
Printed in USA.
0498M
Line Extender III PHD — 5-40/52-750 MHz
Data is based on stations configured for 2-way operation.
ORDERING INFORMATION
Housing — 1 Required
• #545443 Uncoated housing, high current passing
• #545444 Coated housing, high current passing
• #548774 High current upgrade kit for LE housing (includes
• #545444 Coated housing, high current passing
• #548774 High current upgrade kit for LE housing (includes
two seizure assemblies & two anvils)
Amplifier Module — 1 Required
• #573900 Forward & Reverse with power supply. Power supply
has 30 V AC undervoltage lockout.
• #590523 Forward & Reverse with power supply. Power supply
has 40 V AC undervoltage lockout.
Required Accessories
• Plug-in Pads (attenuators):
– 2 required for forward (1 input, 1 interstage)
– 1 required for reverse (1 output)
– 1 optional for reverse (1 input)
– 1 required for AGC option
Available in 0.5 dB steps from 0 to 20 dB. Order Model PP-*
(* denotes pad value), specify value.
– 1 required for reverse (1 output)
– 1 optional for reverse (1 input)
– 1 required for AGC option
Available in 0.5 dB steps from 0 to 20 dB. Order Model PP-*
(* denotes pad value), specify value.
• Plug-in Forward Input Equalizer, 1 required. Available in 1.5 dB
steps from 0 to 28.5 dB at 750 MHz. Order Model EQ750-*
(* denotes equalizer value), specify value.
(* denotes equalizer value), specify value.
• Reverse Equalizer, Variable or Fixed, 1 required (reverse
output), select one of either type:
Variable Reverse Equalizers
Variable Reverse Equalizers
#511075
1.5 to 4.5 dB at 40 MHz
#511295
4.5 to 7.5 dB at 40 MHz
#511298
7.5 to 12.0 dB at 40 MHz
Fixed Reverse Equalizers
Available in 1 dB steps from 1 to 12 dB at 40 MHz. Order
Model EQ40S-* (* denotes equalizer value), specify value.
Available in 1 dB steps from 1 to 12 dB at 40 MHz. Order
Model EQ40S-* (* denotes equalizer value), specify value.
• One of the following interstage accessories is required for most
applications:
#539578
445.25 MHz single pilot AGC with 9 dB fixed
value interstage equalizer
value interstage equalizer
#503100
Thermal compensator with 3-9 dB variable
interstage equalizer
interstage equalizer
#511380
3-9 dB variable interstage equalizer
Optional Accessories
• #467351 230 VAC Crowbar Surge Protector
• Plug-in Cable Simulator. Simulates cable losses, creating tilt
• Plug-in Cable Simulator. Simulates cable losses, creating tilt
opposite that of equalizers. Use in place of forward input
equalizer as needed to maintain proper output tilt in short
spaced locations. Available in 1.5 dB steps from 1.5 dB to
12.0 dB cable loss at 750 MHz. Order Model CS 750-*
(* denotes CS value), specify value.
equalizer as needed to maintain proper output tilt in short
spaced locations. Available in 1.5 dB steps from 1.5 dB to
12.0 dB cable loss at 750 MHz. Order Model CS 750-*
(* denotes CS value), specify value.
• Interstage Trim Network,. Type and use factor is determined by
evaluating actual system frequency response. Use as needed.
Related Equipment
• #501111 Long Reach Test Point Adapter
• #276982 Reverse Injection Probe (3 dB insertion loss)
• #143190 Cable Seizure Wrench
• #276982 Reverse Injection Probe (3 dB insertion loss)
• #143190 Cable Seizure Wrench
MECHANICAL SPECIFICATIONS
Housing Dimensions
11.5 in. L x 9.5 in. H x 4.0 in. D
292.1 mm L x 241.3 mm H x 101.6 mm D
292.1 mm L x 241.3 mm H x 101.6 mm D
Weight
Housing 6 lbs, 6 oz; 2.9 kg
Module 2 lbs, 13 oz; 1.3 kg
Module 2 lbs, 13 oz; 1.3 kg
Specifications and product availability are subject to change
without notice.
without notice.
Scientific Atlanta and the Scientific-Atlanta logo are registered
trademarks of Scientific-Atlanta, Inc.
trademarks of Scientific-Atlanta, Inc.
Surge Resistant is a trademark of Scientific-Atlanta, Inc.