Cisco Netcrypt Bulk Encryptor Guida All'Installazione
Download Software to the GoQAM Modulators
78-4024239-01 Rev B
23
Resetting One GoQAM
1 If necessary, open an xterm window on the DNCS.
2 Type the following command and press Enter:
1 If necessary, open an xterm window on the DNCS.
2 Type the following command and press Enter:
auditQam -reset [GoQAM ip address]
Result: The system shuts down and reinitializes the modulator.
Note: The system also performs an audit to ensure that the session list for the
Result: The system shuts down and reinitializes the modulator.
Note: The system also performs an audit to ensure that the session list for the
modulator matches the session list from the DNCS.
3 Do you see the IP address for the modulator you reset in the bootpd log file?
If yes, continue with this procedure.
If no, call Cisco Services.
4 Select one of the following options:
For modulators that carry broadcast sessions, go to Verifying the
Functionality of GoQAM Modulators That Carry Broadcast Sessions (on
page 25).
For modulators that carry xOD or VOD sessions, go to Verifying the
Functionality of GoQAM Modulators That Carry xOD or VOD Sessions (on
page 26)
Resetting More Than One GoQAM
When performing an upgrade, you may not want to manually reset hundreds of
When performing an upgrade, you may not want to manually reset hundreds of
modulators from the DNCS GUI. To save time, you can create a script that resets the
modulators. Refer to the following example for a sample script.
Important: Resetting the modulator interrupts all active sessions on the modulator
Important: Resetting the modulator interrupts all active sessions on the modulator
for up to 10 minutes. Complete this task during a maintenance window whenever
possible.
This sample script will execute the following functions:
This sample script will execute the following functions:
Reset four modulators.
After 5 minutes (300 seconds), reset another set of four modulators.
Important: Use the procedure for
Preparing to Monitor Remote GoQAM Resets (on
page 20) when using an auditQam script to reset multiple modulators.
Note: You can save and re-use this script each time you need to reboot your
Note: You can save and re-use this script each time you need to reboot your
modulators.