Cisco DataLINXS Rack Mount Fiber Optic Enclosures Scheda Tecnica
2
Specifications
Specification
Units
Standard Grade
Premium Grade
Insertion Loss (@1310 nm, 1550 nm) Singlemode
Multimode
dB
dB
dB
0.30
0.50
0.50
0.20
0.40
0.40
Return Loss (@1310 nm, 1550 nm)
APC ferrule end face finish (singlemode)
UPC ferrule end face finish (singlemode)
PC (multimode)
PC (multimode)
dB
dB
dB
dB
dB
>60
>55
>40
>55
>40
>60
>55
>40
>55
>40
End Face Geometry
Meets tolerances of
Telcordia GR-326 Issue 3
Tighter tolerances than
Telcordia GR-326 Issue 3
Length Tolerance
1 to 10 meter lengths
>10 meter lengths
m
m
m
±0.1
±0.3
±0.3
±0.1
±0.3
±0.3
Operating Temperature
°C
-40 to +65
-40 to +65
Testing for Insertion Loss & Return Loss
100%
100%
Notes:
•
Connectors meet the dimensional requirements of the TIA/EIA-604 FOCIS specification.
•
FC/APC connectors meet the TIA/EIA-604-4A, Narrow Key, k=3 specification.
•
Each jumper is shipped in a separate, re-sealable bag, labeled with the appropriate S-A jumper configuration code, S-A part number (if applicable), and date of manufacture.
Ordering Information for Standard Jumpers
Standard Fiber Jumper Lengths
Part Numbers (by length)
Description
1m
3m
5m
10m
15m
Singlemode Simplex
SC/APC to SC/APC
SC/APC to SC/APC
4000665
4000666
4000667
4000668
4000669
SC/UPC to SC/UPC
4000670
4000671
4000672
4000673
4000674
FC/APC to FC/APC
4000675
4000676
4000677
4000678
4000679
FC/UPC to FC/UPC
4000681
4000682
4000683
4000684
4000685
LC/UPC to LC/UPC
4000686
4000687
4000688
4000689
4000690
E2000/APC to E2000/APC
4000691
4000692
4000693
4000694
4000695
Hybrid Singlemode Simplex
SC/APC to FC/APC
SC/APC to FC/APC
4000647
4000648
4000649
4000650
4000651
SC/APC to SC/UPC
4000652
4000653
4000654
4000655
4000656
SC/APC to FC/UPC
4000657
4000658
4000659
4000660
4000661
SC/UPC to FC/UPC
751751
Hybrid Singlemode Duplex
SC/PC to LC/PC
SC/PC to LC/PC
4000662
—
4000663
4001002
4000664
Multimode Simplex
SC/PC to SC/PC (62.5/125)
SC/PC to SC/PC (62.5/125)
—
—
4000602
—
—
SC/PC to SC/PC (50/125)
—
—
4000603
—
—
Multimode Duplex
SC/PC to SC/PC (62.5/125)
SC/PC to SC/PC (62.5/125)
—
—
4000604
—
—
SC/PC to SC/PC (50/125)
—
—
4000605
—
—
MT-RJ to MT-RJ (62.5/125)
4000607
4000608
4000609
4000610
4000611
MT-RJ to MT-RJ (50/125)
—
—
4000612
—
—
Hybrid Multimode Duplex
SC/PC to MT-RJ (62.5/125)
SC/PC to MT-RJ (62.5/125)
4000613
4000614
4000615
4000616
4000642
SC/PC to MT-RJ (50/125)
—
—
4000643
—
—
SC/PC to LC/PC (62.5/125)
4000644
—
4000645
—
4000646
SC/PC to MT-RJ (62.5/125)
4000801
4000802
4000803
Fiber Management – Prisma
Fiber Optic Jumpers