Cisco Laser Link Return Digital Receiver with Ethernet Scheda Tecnica

Pagina di 3
Laser Link Mainframes 
 
2
 
 
 
Specifications 
 
Mainframe 
Electrical 
Units 
AC and DC Versions 
Output Voltage 
(Nominal)
 V 
DC 
24 
Ripple and Noise 
(Max.)
 
(Output Volt = 24 V) 
1% peak-to-peak 
Output Current 
(Max.) 
1
  
amps 15.6 
Output Power 
(Max.)
 W 
375 
Specified Temperature Range  
°F (°C) 
-4 to 149 (-20 to 65) 
 
 
AC Version 
DC Version 
Input Voltage Range 
2
 
85-264 
2
 
40 ~ 60 
Input Current 
3
 
amps n/a 
12 
Fuse Type 
 
8 amp AC input line fuse 
15 amp thermal  
magnetic breaker 
 
Safety Approvals 
Units 
Specification 
Safety Agency Approvals 
 
CSA 22.2 No. 234, U.L.® 1950, EN 60950, CE 
Physical 
 
 
Operating Temperature  
°F (°C) 
4 to 149 (-20 to 65) 
Relative Humidity
 (Non condensing)
 % 
5-95% 
Mounting 
in. (cm) 
Standard 19 (48.26) rack/optional 23 (58.42) 
Dimensions (H x W x D)  
in. (cm) 
8.75 x 19 x 21.1 (22.23 x 48.26 x 53.59) 
Weight 
lbs. (kg) 
32 (14.5) 
Notes: 
1.  Derated for temperature, 65 °C 
2.  AC input range selection is fully automatic 
3.  Typical @ 48 V dc and maximum output current 
 
 
Mini-Mainframe 
Power 
Units 
Specification 
Input Current 
amps 
2.5 @ -48 V DC 
2 @ 120 V AC 
Output Power 
(Max.)
 W 
100 
Output Voltage 
V DC 
24 ±2.5% 
Front Alarm 
 
 
“A” Supply, “B” Supply  
>26.4 
<21.6 
Physical 
 
 
Operating Temperature  
°F (°C) 
-4 to 149 (-20 to 65) 
Relative Humidity 
(Non condensing)
  
20-100% 
Mounting  
in. (cm) 
Standard 19 (48.26) and 23 (58.42) rack 
Dimensions (H x W x D) 
in. (cm) 
3.5 x 19 x 19 (8.89 x 48.26 x 48.26) 
Weight  
lbs. (kg) 
15 (6.80)