Cisco Cisco Prisma II EDR Receiver Guida All'Installazione

Pagina di 47
78-715189-01 Rev C 
Operation 
3-5 
Ensuring a Flat Output Signal by Adjusting the Step Equalizer 
Variable Equalizer Adjustment Procedure 
Important: The following procedure assumes that you have adjusted the variable 
pad, if necessary, to ensure that the signal strength is correct. 
For your system to operate properly, the output signal must remain flat across all 
channels. To use the step equalizer to ensure that the output signal is flat, follow 
these steps. 
1. 
On the back of the chassis, locate the amplifier’s RF output port. 
Note: HEDA output connectors are on Port B row. 
2. 
Using a 7/16-in. open-end wrench, disconnect the RF cable designated for the 
RF output of the amplifier and connect a test cable from the RF output 
connector to a spectrum analyzer. Torque the connector to the specifications 
given by the connector manufacturer. Do not over tighten
3. 
Measure the output level at the highest system frequency and lowest system 
frequency. 
4. 
Use the following formula to determine output tilt.  
Tilt = L
High
 - L
Low
 
Where: 
Tilt  = amplitude difference between the highest and lowest frequency 
L
High
 = signal level of the highest frequency 
L
Low
 = signal level of the lowest frequency 
5. 
Using a 
1
/
8
-in. flat-blade screwdriver, turn the tilt setting on the front panel of 
the amplifier so the signal is flat across all channels. Refer to the following 
table: 
 
 
Amount of Signal Equalization 
  Tilt Setting 
Forward 
Reverse 
 
0.0 dB 
 0.5 dB   
 
1.0 dB 
 1.5 dB   
 
2.0 dB 
 2.5 dB   
 
3.0 dB 
 3.5 dB   
 
4.0 dB 
 4.5 dB   
 
MAX 
5.0 dB 
 5.5 dB