Cisco Cisco OptoStar II 1550nm EDFA Guida All'Installazione
Operating using Console Software, Continued
Setup Parameters
The table below lists the setup parameters of the OptoStar II 1550 nm optical
amplifier module.
amplifier module.
Setup Parameters Description
Factory Default
Laser Status
ON/OFF
Shows/sets laser status: ON/OFF Laser Status: OFF
Optical input
power alarm
threshold
Shows/sets optical alarm upper
limit and lower limit
Lower limit: - 5.0 dBm
Upper limit: + 10.0
Upper limit: + 10.0
dBm
Optical output
power alarm
threshold
Shows/sets optical alarm upper
limit and lower limit
Lower limit: standard
value - 4.0 dBm;
Upper limit: standard
Upper limit: standard
value + 1.0 dBm
Alarm ON/OFF
Shows/sets module alarm status:
ON/OFF
Alarm status: ON
Restart setting
Sets up restart of the optical
amplifier
--
Factory Setting
Restores the factory settings of
the optical amplifier
--
3-22
Operation
OL-29666-02