Cisco Cisco OptoStar II Driver Amplifier Guida All'Installazione

Pagina di 82
General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-14) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
High Drive / 
TEC Current 
Automatic power control 
circuit failure 
Contact the manufacturer for 
servicing 
High Laser 
Temperature 
 
Laser failure 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
Contact the manufacturer for 
servicing 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Ensure good ventilation   
 
Put the chassis in a place 
with good ventilation 
 
In case of fan failure, 
replace the fan, or 
contact the manufacturer 
for servicing 
Low or High 
Optical Input 
Power 
 
Optical source failure   
 
Fiber or connector 
failure   
 
Make sure the optical 
connector matches 
 
Make sure the fiber 
works well   
 
Check whether the 
optical input power is 
between -5.0 dBm and 
10.0 dBm with an optical 
power meter 
 
If the input power is 
normal, contact the 
manufacturer for 
servicing 
 
 
Continued on next page 
4-4 
Troubleshooting 
OL-29666-02