Cisco Cisco OptoStar II Driver Amplifier Guida All'Installazione

Pagina di 67
Operating using ICIM LCD, Continued 
Sub-Menu 1 -- Optical Input Information 
The illustration below shows sub-menu 1 of the OptoStar II optical switch module 
- Optical Input Information. 
 
By default, the optical input power switching threshold lower limit is -15 dBm, 
upper limit is 25 dBm. The setup range is -15 dBm to +25 dBm, with 0.1 dB step. 
The cursor stays in the “Low” field. 
• 
To configure the lower limit of the optical power switching threshold 
(minimum output power is no less than -15 dBm):   
1.  Press SET button to start the configuration; 
2.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
3.  Press ► button to move the cursor to “Set”; 
4.  Press SET button to save the configuration. 
• 
To configure the upper limit of optical power switching threshold (maximum 
output power is no more than 25 dBm):   
1.  Press ▼ button to move the cursor to the “High” field; 
2.  Press SET button to start the configuration; 
3.  Press ▲▼ buttons to change the value, and press SET button to confirm; 
4.  Press ► button to move the cursor to “Set”; 
5.  Press SET button to save the configuration. 
The optical input power values of channel A and channel B can be viewed on the 
right side of the screen. 
 
Continued on next page 
 
 
OL-29670-02 
Operation 
3-7