General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-15) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause  Servicing Instruction 
Low or High 
RF Input 
Level 
Low or High 
RF Output 
Level 
 
RF source 
failure   
 
RF cable or 
connector 
failure   
 
Make sure the RF connector matches   
 
Make sure the cable works properly 
 
Inspect if the RF input signal level 
meets the specifications 
The specifications are: 
1.  If the RF input signal has only an 
analog signal, the analog signal 
input level is 15 ± 5 dBmV/channel 
at the broadcast RF input port. 
Recommended input level: the 
analog signal is 15 dBmV/channel 
at the broadcast RF input port.   
2.  If the RF input signal has both 
analog signal and digital signal, the 
analog signal input level is 15 ± 5 
dBmV/channel at the broadcast RF 
input port; digital signal input level 
is 9 ± 5 dBmV/channel at the 
broadcast RF input port; and digital 
signal input level is 21 ± 5 
dBmV/channel at the narrowcast 
RF input port.   
Recommended input level: the 
analog signal is 15 dBmV/channel 
at the broadcast RF input port; the 
digital signal input level is 9 
dBmV/channel at the broadcast RF 
input port; and the digital signal 
input level is 21 dBmV/channel at 
the narrowcast RF input port. 
3.  If the RF input signal has only 
digital signal, the digital signal 
input level is 15 ± 5 dBmV/channel 
at the broadcast RF input port.   
Recommended input level: the 
digital signal is 15 dBmV/channel 
at the broadcast RF input port. 
 
If the input level is normal, contact the 
manufacturer for servicing 
 
Continued on next page 
4-4 
Troubleshooting 