Starting up the Module 
Initialization 
When the OptoStar II platform is powered on, all modules will perform a self-test. 
Follow these steps to perform the self-test: 
1.  Turn the front panel switch of the OptoStar II power supply module to ON 
position. 
2.  When the OptoStar II platform starts up, it will perform a booting 
initialization. 
3.  During the initialization, the LEDs on the front panels of all modules will be 
illuminated, and the communication status is shut off.   
4.  Once the initialization is completed, the status indicator will return to normal. 
Communication is enabled and the module is operational. 
CAUTION:   
• 
The module must be initialized; any equipment that cannot be initialized must 
be returned to the manufacturer for repair. 
• 
When everything becomes stable, the module still needs to warm up for at least 
one hour, to make sure that its performance is normal. 
 
 
 
 
 