Operating using ICIM LCD, Continued 
Sub-menu 1 -- RF Input   
The illustration below shows sub-menu 1 of the OptoStar II RF switch module – 
RF Input Power.   
 
The RF input information shows/sets input level calibration and shows the RF 
input level value of channel A.   
Input RF signal respectively from channel A and channel B RF input ports. 
Channel A signal is always for calibration. The cursor stays at “Calibrate”. Press 
SET to calibrate and save the configuration. The channel A value will change to 
“00.” Compare the channel A and channel B signals and display the result. If the 
deviation is within the threshold (default value is 3 dB), it passes calibration and 
channel A starts to work in auto mode. If the deviation is beyond the threshold, 
the alarm will be triggered and channel A starts to work in auto mode. The table 
below lists auto switching status under different conditions in the auto mode (1 
stands for alarm; 0 stands for normal). 
Item 
Alarm Status  Switching 
Status 
Description 
Working in channel A 
Working in channel A 
3* 
Working in channel B 
A/B 
Staying in the previous working channel 
Note: In item 3*, if the optical input in channel A is normal, and performs 
continuous monitoring for 15 seconds, it will switch to channel A automatically, 
with 0.5 dB of delay. 
 