Cisco Cisco E-Mail Manager Unity Integration Option Riferimenti tecnici
52
Eicon Card Configuration
52
4.1. Eicon Card Configuration Details
1.
Select the High-Level Protocols node. The High Level Protocol
selected should be Transport ISO and left as no choice.
selected should be Transport ISO and left as no choice.
2.
Select the Port 1 node. Enter the following values:
Port Name
P1
Number
1
Protocol
X.25
Dialer
Direct
3.
Select the X.25 node. Enter the following values:
Node type
DTE
Packet format
Extended
X.25 Version
1984
Window size
Maximum = 7, Default = 2
Packet Size
Maximum = 128, Default = 128
4.
Select the VC Tab to check entitled Sequential assignment of virtual
circuits.
circuits.
Number of PVC
0
Number of IVC
0
Number of TVC
4
Number of OVC
0
Note the Value in the Number of TVC must match x in the (SVC2WAY x)
in the DMS100 datafill MPCLINK table, if when the DMS100 PIM sends
open connection request, the DMS100 switch rejects the connection
request with a DIAGONISTC code.
in the DMS100 datafill MPCLINK table, if when the DMS100 PIM sends
open connection request, the DMS100 switch rejects the connection
request with a DIAGONISTC code.
In the Timer Tab
T20
180
T21
200
T22
180
T23
180
Idle
0
Acknowledge
10z