Best Practices for Using the System Health
Report
l
Verify your system regularly to be sure that the StadiumVision health report is
being sent as expected:
o
Confirm your health report email configuration.
o
Check often with venue IT personnel that the SMTP server that that is
configured for the StadiumVision health report is running normally.
l
Review the StadiumVision health report daily to monitor the media players and
overall health of the Cisco StadiumVision Director system.
l
Investigate all of the devices reported in the "Devices in critical state" and the
"Devices not reachable" sections.
NOTE: The device counts in these two sections are typically
equal, but not necessarily. For example, for the Cisco DMP
4310G, a Flash Template corruption or missing Flash Template
will show up as “critical” but not “unreachable.”
o
Inform the Event Manager about these devices.
o
Investigate the affected devices and bring to Normal state. Replace if
necessary.
o
Do not ignore the devices reported in these sections. The media players almost
always will be showing black screens on the TV displays.
l
If you see that an unusual number of devices have recently rebooted, investigate
further. This could be due to a power fluctuation issue in the edge switch,the edge
switch itself was rebooted, or another issue caused a break in power supply to the
affected devices.
l
Non-compliant devices:
o
If you know that you normally have a certain number of devices in non-
compliant state, then ignore this entry.
o
If the number of non-compliant devices is not what you expect, investigate and
correct the issue(s).