Cisco Cisco Prisma II ICIM Guida All'Installazione
Chapter 2 Module Installation
28
78-4023013-01 Rev C
To Connect Chassis-to-Chassis ICIM IN and ICIM OUT Ports
1 Connect the serial extension cable from the ICIM OUT of the chassis containing
the ICIM to the ICIM IN connector of the second chassis.
2 Connect a serial extension cable from the ICIM OUT of the second chassis to the
ICIM IN of the third chassis.
3 Continue this “daisy-chain” connection until all chassis are connected.
4 Connect an ICIM OUT terminator, part number 4013014, to the ICIM OUT
4 Connect an ICIM OUT terminator, part number 4013014, to the ICIM OUT
connector on the last chassis in the daisy-chain connection. The ICIM OUT
terminator ships with the ICIM.
Important:
All chassis connected in the daisy-chain must be powered and have a fan tray
installed. A chassis connected in the daisy-chain that is not powered or has no
fan tray installed will cause faulty operation of the ICIM.
All chassis connected in this daisy-chain must have a unique chassis ID number.
If the ICIM OUT terminator that ships with the ICIM is not installed on the last
chassis of a daisy-chain connection, faulty communication with the ICIM may
occur.