General Information 
78-4028521-01 Rev B 
Laser Link III Mainframe Description,
 Continued 
Fan Assembly 
The fan assembly in the Laser Link III Mainframe is controlled by the processor.  
Power and signals are routed from jumper cable J6 on the fan assembly to J19 on the 
power distribution board.  The fan assembly is accessible through a removable panel 
on top of the assembly.  However, a minimum of 1 RU is needed for this access.  See 
Chapter 2, Installation, for guidance on selecting a location to install the mainframe. 
As shown in the following diagram, as a module is plugged into a particular slot in 
the mainframe, a corresponding fan will turn on. 
 
 
 
Individual fans are monitored for rotation. If rotation is not detected, a fan alarm is 
generated causing the ALARM LED to flash red.