Cisco Laser Link Return Digital Receiver with Ethernet Guida All'Installazione

Pagina di 53
3-18 
Setup and Operation 
78-4028521-01 Rev B 
Alarm Tables,
 Continued 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
LLFR 
Laser Link full-
width 50-750 MHz 
and 45-870 MHz 
forward receiver, 
front panel optical 
connector 
#1/#5 
  
  
  
#2/#11  
#3/#12 
  
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Receive Power 
Loss of RF Alarm (< +31 
dBmV total power) 
Global Alarm – optical 
receive power < -10 dBm, 
“A” supply fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
5 V = normal 
0 V = alarm 
24 V = normal 
0 V = alarm 
 
1550 nm DFB Forward Transmitters Alarm Table 
 
Models 
(front panel 
label) 
Description 
Vital Sign 
VS#/Pin# 
Vital Sign Description 
Logic 
LLNT 
Laser Link LLNT 750 
MHz and 870 MHz 
1550 nm transmitter 
for DWDM 
applications 
#1/#5 
  
  
  
#2/#11 
#3/#12 
#4/#4 
Redundant Power Alarm 
– active when module 
detects loss of +24 V DC 
“A” supply 
Optical Output Power 
Laser Bias Current  
Global Alarm – +5 V DC 
fails, laser temp ±5%, laser 
bias current ±10%, optical 
power – 25%, “A” supply 
fails 
0 V = normal 
+5 V = alarm 
  
  
1 V/mW 
1 V/50 mA 
24 V = normal 
0 V = alarm