Cisco Cisco Firepower Management Center 4000

Pagina di 45
Version 5.2.0.6
Sourcefire 3D System Release Notes
36
Known Issues
In some cases, the system incorrectly identifies SMTP and generates a 
connection event with missing application information if the SMTP server 
responds with a connection error. (130085)
In rare cases, the system may generate critical health alert emails 
containing indecipherable messages. (130518)
In some cases, the system may incorrectly sort values in the Type column or 
omit names from the Security Zones column on the security zones page in 
the object manager. (130569, 130631, 130632)
In some cases, drilling down in a custom workflow may redirect you to the 
incorrect packet view page for an intrusion event. (130620)
In some cases, the system restore boot option does not output to the serial 
port on managed devices even if you selected Physical Serial Port as the 
remote console access option. (130772)
In several places, the documentation incorrectly indicates that you can add 
IP address ranges to network objects. The Sourcefire 3D System currently 
supports adding individual IP addresses or address blocks to network 
objects, not ranges. (130821, 130992)
In some cases, 3D8250, 3D8260, 3D8270, and 3D8290 managed devices 
with 10G or 40G NMSB may experience compatibility issues with 10G 
NFTW NetMods. To be compatible with 10G NFTW Netmods, 10G NMSB 
must be revision 7 or later and 40G NMSB must be revision 8 or later. 
(131189)
In rare cases, the table view of servers (Analysis > Hosts > Servers) may 
duplicate servers and produce inaccurate server counts. (131329)
The eStreamer client omits file policy UUID metadata from type 502 
intrusion events. (131362)
If you schedule multiple simultaneous reporting tasks when using remote 
storage, the system may fail to send all reports to the selected remote 
storage location. As a workaround, schedule report generation tasks in 
30-minute intervals. (131805)
Sourcefire documentation does not reflect that you must disable Spanning 
Tree Protocol (STP) on any third-party switching equipment connected to a 
device’s management interface before connecting to a Series 3 appliance 
using LOM/SOL. (132488)
If Greenwich Mean Time (GMT, also known as UTC) is not your local 
timezone, scheduled geolocation database (GeoDB) updates may fail. If 
your local timezone is +X number of hours from GMT, schedule GeoDB 
updates for 
X:00
 or later. If your local timezone is -X number of hours from 
GMT, schedule GeoDB updates for 
(24:00 - X)
 or earlier. For example, if 
your local timezone is UTC-5, schedule updates before 
19:00
 local time. 
(135756)