Table 5 describes the LED states when the board is powered up and the 10/100 Mbits/sec LAN 
subsystem is operating. 
Table 5. 
LAN Connector LED States 
LED Color 
LED State 
Condition 
Off 
LAN link is not established. 
On 
LAN link is established. 
Green  
Blinking 
LAN activity is occurring. 
Off 
10 Mbits/sec data rate is selected 
Yellow 
On 
100 Mbits/sec data rate is selected 
1.9.2  LAN Subsystem Software 
LAN software and drivers are available from Intel’s World Wide Web site. 
For information about  
Refer to 
Obtaining LAN software and drivers 
1.10  Hardware Management Subsystem 
The hardware management features enable the Desktop Boards to be compatible with the Wired for 
Management (WfM) specification.  The Desktop Board has several hardware management features, 
including the following: 
•  Fan monitoring and control (through the hardware monitoring and fan control ASIC) 
•  Thermal and voltage monitoring 
•  Chassis intrusion detection 
1.10.1  Hardware Monitoring and Fan Control ASIC 
The features of the hardware monitoring and fan control ASIC include: 
•  Internal ambient temperature sensor 
•  Two remote thermal diode sensors for direct monitoring of processor temperature and ambient 
temperature sensing  
•  Power supply monitoring of five voltages (+5 V, +12 V, +3.3 VSB, +1.5 V, and +VCCP) to 
detect levels above or below acceptable values 
•  Thermally monitored closed-loop fan control, for all three fans, that can adjust the fan speed or 
switch the fans on or off as needed 
•  SMBus interface 
 
 
For information about  
Refer to 
The location of the fan connectors and sensors for thermal monitoring