This release note describes the features and capabilities included in the Cisco TelePresence System 
C/MX/EX-Series codec software version TC4.2.4 released on 9
th
 of October 2012.
 
Note: Please read the known limitations section if you use TMS to upgrade your system from any 
release prior to TC4.0.0 
Hardware compatibility 
Due to replacement of hardware components there are some constraints running older software on 
newly manufactured endpoints. This is due to end of life of some components and introduction of new 
components that require support in the software.  Executing the API 
xcommand xstat SystemUnit 
Hardware Module CompatibilityLevel will reveal if there are any constraints on the system. For a 
detailed list of compatibility levels and software constraints for the Cisco TelePresence systems 
please see the appendices in this document: 
- HW dependencies – Compatibility Levels Cisco TelePresence Systems
 
- HW dependencies – Compatibility Levels Cisco TelePresence Touch 8
 
 
NAND Flash 
The Cisco TelePresence endpoints are using a NAND flash memory for general storage and transfer 
of data. The endpoints running TC software will be manufactured with a new version of the flash 
memory. For simplicity we will call the first flash version 0 and the second flash version 1. There will 
probably be more versions. Endpoints having version 1 of the flash memory must run software 
TC3.1.5 and later, 4.2.0 and later or 5.0.0 and later. Please check the release note to find if the new 
version of the flash memory is supported. If your endpoint does not have the CompatibilityLevel 
command it will have flash version 0 installed which means no software constraints. 
 
Internal Camera 
For units with internal camera (EX60/EX90 and MX200/MX300) the camera software is embedded into 
the application software. Units shipped with the E4 sensor cannot be downgraded or upgraded to any 
software version lower than TC4.2.4 or TC5.1.1 unless support is specifically documented in the 
release notes for the software you are downgrading to. 
MX300 is not supported in TC4. 
To check which camera sensor the EX-series or MX-series product has, execute the API command 
xstatus camera HardwareID  
 
This example shows an EX60 with the E3 sensor, which means that it can be downgraded to versions 
earlier than TC4.2.4 or TC 5.1.1: 
Example: 
xstatus camera HardwareID  
*s Camera 1 HardwareID: "e3:0xd30a" 
** end 
If a system shipped with the E4 sensor is attempted to downgrade to an unsupported software 
version, the software downgrade will fail and the unit will reboot, keeping its existing software version. 
From TC5.1.3 there is a lock which prevents the system from downgrading to an unsupported version.