Samsung AQ09TSBNEUR Manuale Utente

Pagina di 43
6
Operation ranges
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the 
table for efficient use.
Maintaining your air conditioner
  If the air conditioner operates in cooling mode for long period of time in high humidity area, dew may be formed.
  If the outdoor temperature goes down to -5°C, heating capacity may decrease as much as 60%~70% of specified capacity 
according to the using conditions.
Mode
Indoor temperature
Outdoor temperature
Indoor humidity
Cooling 
16˚C~32˚C
15˚C~43˚C
Relative humidity 80% or less
Dry
18˚C~32˚C
15˚C~43˚C
-
Heating
27˚C or less
-5˚C~24˚C
-
Internal protections via the unit control system
 This internal protection operates if an internal fault occurs in the air conditioner.
Type
Description
Against cold air
The internal fan will be off to against cold air when the heat pump is heating.
De-ice cycle
The internal fan will be off to against cold air when the heat pump is heating.
Anti-protection of  
internal battery
The compressor will be off to protect internal battery when the air conditioner operates 
in Cool mode.
Protect compressor
The air conditioner does not start operating immediately to protect the compressor of 
the outdoor unit after it has been started.
•   If the heat pump is operating in Heat mode, De-ice cycle is actuated to remove frost from an outdoor unit that may
have deposited at low temperatures. 
The internal fan is switched off automatically and restarted only after the de-ice cycle is completed.
Checking before use