 3 Cabling and configuration
30
Join/Split bus jumper
The ESM/CSM has a jumper located on it that forces the SCSI bus into 
joined or split mode.  This jumper is located on the ESM/CSM PCB at 
location JP10.  
To access the jumper:
1.
Remove the ESM/CSM from the enclosure.  
2.
Remove the top cover from the ESM/CSM and locate jumper JP10. 
The following table explains the jumper settings:
i/O Module
Jumper 
JP 10
Bus State
ESM
a
a. The overall cable length in joined bus mode is 10 meters.  Any combination of cable
lengths is allowed, so long as 10 meters is not exceeded.
Installed
Removed
2 cables attached, bus is Force Joined
Depends on c able configuration
CSM
b
b. The overall cable length can be 50 meters (25 meters from each I/O module connector to
the host system.  
Installed
Removed
2 cables attached, bus is Force Split
Depends on c able configuration