Acer aspire 4251 Manuale

Pagina di 5
       
Control Number : SACU0910001 
                                                                                                                                             
本資料為新普科技股份有限公司之智慧財產權,非經本公司書面授權許可,不得透露或使用本資料,亦不得複印、複製或轉變成其它任何形式使用。 
The information contained herein is the exclusive property of SIMPLO TECHNOLOGY CO., LTD, and shall not be distributed, reproduced, or disclosed in whole 
or in part without prior written permission. 
本測試報告僅對上述測試項目有效,本報告分離使用無效 
This test report is valid only to the items, Invalid for separation using. 
 
Page 2 of 5 
1. Purpose of the Test
 
To test each cell/battery is of the type proved to meet the requirements in the Recommendations 
on the TRANSPORT OF DANGEROUS GOODS, Manual of Tests and Criteria, Fourth revised 
edition. 
 
2. Test Quantity
 
2.1
  Four batteries, at first cycle, in fully charged states. (T.1~T.5 test only) 
2.2
  Four batteries, at first cycles, in fully discharged states. (T.1~T.5 test only) 
2.3
  Four batteries, after fifty cycles ending in fully charged states. (T.1~T.5 test only) 
2.4
  Four batteries, after fifty cycles ending in fully discharged states. (T.1~T.5 test only) 
2.5
  Five component cells, at first cycle at 50% of the design rated capacity. (T.6 test only) 
2.6
  Five component cells, after fifty cycles ending in fully discharged states. (T.6 test only) 
2.7
  Four batteries, at first cycle, in fully charged states. (T.7 test only) 
2.8
  Four batteries, after fifty cycles ending in fully charged states. (T.7 test only) 
 
3. Test Equipment
 
3.1
  SMP -711 life cycles test system × 32 channel(ML-052,ML-053) 
3.2
  Vacuum Tank x1(ML-308) 
3.3
  Agilent -Digit-multi-meter 6 1/2 34401A x1(ML-257) 
3.4
  Micro-Electronic scale x1(TD-166) 
3.5
  WIT-Thermal shock chamber x1(ML-018) 
3.6
  King Design -Vibration Testerx1 (ML-233) 
3.7
  King Design -Shock tester x1 (ML-056) 
3.8
  WITGROUP- Programmable Temperature & Humidity Chamberx1 (ML-010) 
3.9
  YOHAGOWA –DR230 Hybrid Recorder x1 (ML-198) 
3.10
  YOHAGOWA –MX100 Recorder x1 (ML-068) 
3.11
  JYI SHENG-Impact tester x1 (ML-076) 
3.12
  ABM –GCD-5030D-Large power supply x4 (ML-140, ML-141, ML-142, ML-143)