121
System
MIDI DEVICE ID
Here you can enter the identification number for
system exclusive data transfer. To enable com-
munication between two VIRUS units - i.e. to
exchange system exclusive data - you must as-
sign the same MIDI DEVICE ID to both units.
01111111111111111112
 1 MIDI
 DeviceId   Omni≤   
61111111111111111154
MIDI CONTROL LOW PAGE
Here you can determine if you want the first 128
parameters (Page A) to be sent to MIDI-Out as
system exclusive data (SysEx) or as MIDI Con-
trollers (Contr). When you set it to ”SysEx”, con-
troller data is disabled on the receive side; if you
set it to ”Contr”, both controller and SysEx data
are received.
01111111111111111112
 1 MIDI CONTROL
 LowPage   Contr≤   
61111111111111111154
MIDI CONTROL HIGH PAGE
Here you can determine if you want the second
128 (Page B) parameters to be sent as system
exclusive data (SysEx) or as MIDI PolyPressure
data (PolyPrs). When you set it to ”SysEx”,
polypressure data is disabled on the receive
side; if you set it to ”Contr”, both polypressure
and SysEx data are received.
01111111111111111112
 1 MIDI CONTROL
 HiPage  PolyPrs≤   
61111111111111111154
 
SYSTEM
MASTER TUNE
Determines the overall pitch of the VIRUS. 0 = A
440 Hz. You can detune the device a half-note
up or down at the most.
01111111111111111112
 1 SYSTEM
 Mastertune   +0≤   
61111111111111111154
ARPEGGIATOR GLOBAL
Enables or disables the arpeggiator globally.
The global parameter overwrites the arpeggia-
tor ON/OFF setting of the individual patches.