ACR Electronics PLB-350C Manuale Utente

Pagina di 32
Y1-03-0244C
  
29 
APPENDIX G - TECHNICAL SPECIFICATIONS 
406 MHz Transmitter 
Frequency 
406 MHz 
Output Power 
greater than 5 watts (typical: 6.3 watts) 
Frequency Stability 
±2 parts per billion/100ms 
Digital Message: 
Format 
 
Long message  
Serialized
1*
 
Message protocol 
Standard Location 
Duration 
520 ms 
Rate 
400 bps 
Encoding 
Biphase L 
Modulation 
±1.1 radians peak 
1* 
Beacons are shipped from ACR with a Serialized code but can be reprogrammed at a service 
center to other coded formats including nationality of registration. 
121.5 MHz Transmitter 
Frequency: 
121.5 MHz 
Frequency Tolerance 
±50 ppm 
Output Power 
>25 mW PEP (typical 80mW) 
Morse Code “P” ID 
Every 50 seconds (approximately) (U.S. Protocol) 
Modulation 
Type 
AM (3K20A3N) 
Sweep Range 
400 to 1200 hZ 
Sweep Rate 
3 Hz 
Duty Cycle 
37.5% 
Morse P 
AM (2K00A2A) 
Antenna 
Frequency 
406.037 & 121.5 MHz 
Polarization 
Vertical 
VSWR 
Less than 1.5:1 
General/Environmental 
Minimum 
Battery 
Operating Life 
+24 hours minimum @ -4°F to +131°F (-20°C to +55°C) 
Battery 
Replacement 
Interval 
Battery  replacement  due  no  later  than  6  years  from  date  of 
manufacture, 5 years from date of install, or after emergency use 
*Batteries meet the UN Classification for Non-dangerous goods 
Size 
of 
beacon 
less 
Antenna 
2.31 x 5.81 x 
1.25 in (5.87 x 14.76 x 3.17 cm) (SARLink™ View) 
2.31 x 5.81 x 1.45 in (5.87 x 14.76 x 3.68 cm) (AquaLink™ View) 
Material 
High-impact and UV-resistant plastic 
Color 
ACR-
treuse™ (High-visibility yellow) 
Weight 
8.9 oz (252 g) without belt clip (SARLink™) 
9.2 oz (260 g) without attachment clip (AquaLink™) 
Strobe Light 
Bright White, I flash per 3 seconds 
Digital Display 
Blue, 1 inch 
Waterproof 
Factory tested to 16.4 ft (5 m) for 1 hour and to 32.8 ft (10 m) for 10 
minutes, both at room temperature 
Buoyancy 
See section 5 
“Distinguishing PLB Features”, page 8 
Temperature Range 
Operating 
-4°F to +131°F (-20°C to +55°C) 
Storage: 
-40°F to +158°F (-40°C to +70°C) 
 
PLB-350C  meets  the  requirements  of  Federal  Communications  Commission 
(FCC)  Part  95  Subpart  K.  For  all  other  type  approval  information,  please  visit 
our website at 
.