ademco vista-100 Manuale Utente

Pagina di 66
Ð 17 Ð
ACCESSING OTHER PARTITIONS
(GOTO Command and Global Arming)
To Access
Another Partition
Each keypad is assigned a default partition for display purposes,
and will show only that partition's information. But, if the user is
authorized, a keypad in one partition can be used to perform
system functions in other partitions by using the G O T O
command. Note that only those partitions authorized and
programmed by the installer can be accessed in this manner.
To GOTO another partition:
READY
1. Enter your security code, then press
Ê✱Ê   +  partition
number (0-9).
Entering partition number 0 will return the keypad to its original
partition.
2.
LOG-ON TO
AAAA
PART. X
COMPLETE
The keypad will remain in the new partition
until directed to go to another partition, or
until 2 minutes has elapsed with no
keypad activity.
AAAA = alpha descriptor programmed by
the installer
X = partition number
Global Arming
The Global Arming option may have been programmed for use
by some users. If Global Arming was enabled for use with your
security code, a keypad prompt (message) will appear after
pressing one of the arming function keys (STAY, INSTANT,
AWAY, MAXIMUM, OFF). Follow the keypad prompts to continue
arming the system. See your installer for detailed instructions on
the use of this feature.
If global arming does not apply to your security code, use the
procedures described in the following pages.
Master Keypad
Operation
A "Master" keypad is one that reflects the status of the entire
system (Partitions 1-8) on its display.  This is useful because it
eliminates the need for a security officer in a building to have to
"log-on" to various partitions from one partition's keypad to find
out where an alarm has occurred.
A description of a typical display follows:
S Y S T E M   1 2 3 4 5 6 7 8
S T A T U S   R R N N A  ✴ B