Axis 20443r2 Manuale Utente

Pagina di 62
AXIS 230
Unit Connections
 
49 
Appendix D - Unit Connections
The D-Sub Connector
The AXIS 230 provides one 9-pin D-sub connector, providing the physical interface for an 
RS-232 port, used for connecting accessory equipment; such as stand-alone Pan/Tilt 
devices for the remote positioning of connected video cameras. 
A diagram of the RS-232 connector, complete with pin assignment table, is shown below.
The Terminal Block
The terminal block is located on the rear panel and provides the interface to a single 
transistor output, two digital inputs, an RS-485 interface and GND. 
This section describes the pinout, interface support and the control and monitoring 
functions provided by the terminal block.
Terminal Block Pinout
Pin
Function
1
CD 
2
- RXD
3
- TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Pin
Function Description
1
GND
2
Digital Input 1
1k internal pull-up. Connect to GND to activate.
3
Digital Input 2
1k internal pull-up. Connect to GND to activate.
4
Digital output
Maximum current sink of 100mA (via logical 0 output.) Handles a maximum voltage of 
24V DC, which is grounded at a maximum of 100mA. This output has an open-collec-
tor NPN transistor with the emitter connected to pin 1. If used with an external relay, 
a diode must be connected in parallel with the load, for protection against voltage 
transients.
5
RS-485-A (non-inverting)
 A half-duplex RS-485/422 interface for controlling auxiliary equipment.
6
RS-485-A (inverting)
5
4
3
2
1
6
7
8
9