Troubleshooting
Checking the Firmware
Firmware is software that determines the functionality of the AXIS 212 PTZ. One of your first actions when 
troubleshooting a problem should be to check the currently installed firmware version. The latest version may 
contain a correction that fixes your particular problem. The current firmware version in your camera can be 
seen on the page Setup > Basic Configuration.
Upgrading the Firmware
When you upgrade the firmware with a file from the Axis Web site, your camera will receive the latest available 
functionality. Always read the upgrade instructions and release notes available with each new release, before 
updating the firmware.
Note: 
Preconfigured and customized settings will be saved when the firmware is upgraded (providing the features are available in the new 
firmware) although this is not guaranteed by Axis Communications. Always read the instructions and release notes available with 
each new release, before upgrading the firmware.
1. Save the firmware file to your computer. The latest version of the firmware is available free of charge 
from the Axis Web site at www.axis.com/techsup
2. Go to Setup > System Options > Maintenance in the camera’s Web pages.
3. In the Upgrade Server section, browse to the desired firmware file on your computer. Click Upgrade.
Notes: 
•After starting the upgrade process, always wait at 
least 5-10 minutes before restarting the camera, even if you 
suspect the upgrade has failed.
•Your dealer reserves the right to charge for any repair attribut-
able to faulty upgrading by the user.
 
 
AXIS Camera Management
 software tool can be used 
for multiple upgrades. Refer to the Axis Web site at 
www.axis.com for more information.
 
Emergency Recovery Procedure
If power or the network connection to the camera is lost during the upgrade, the process will fail and the unit 
will become unresponsive. A flashing red Status LED indicates a failed upgrade. To recover the unit, follow the 
steps below. The serial number is found on the label attached to the bottom of the camera.
1. Unix/Linux - From the command line, type the following: 
arp -s <IP address of camera> <Serial number> temp 
ping -s 408 <IP address of camera> 
 
Windows - From a command/DOS prompt, type the following: 
arp -s <IP address of camera> <Serial number> 
ping -l 408 -t <IP address of camera>
2. If the unit does not reply within a few seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.
3. Open a browser and type in the camera’s IP address. In the page that appears, use the Browse button to 
select the upgrade file to use, e.g. axis212ptz.bin. Then click the Load button to restart the upgrade process.