Axis 25205 Manuale Utente

Pagina di 8
290B Outdoor housing
Maintenance
Annual maintenance is required to inspect all visible seals for wear and damage. Worn or 
damaged seals should be replaced. 
Recommendation:
 Treat all visible seals with silicone at least once a year to prevent them 
from drying out and to aid opening and closing of the housing. Use an all-purpose silicone 
spray for use on electrical equipment and components, and also compatible with rubber, 
metal and plastic materials.
Clean the housing with a damp cloth only (not on the window). Do not use chemicals to 
clean the housing as this may affect the powder coat finish. The window should only be 
cleaned with a dry cloth.
Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the 
camera. Use a 5A, 250 V AC fuse and ensure that the mains is disconnected before 
beginning.
Specifications 
Weight
Power requirements
Operating temperature
Approx. 6 lbs  
(2,75 kg) 
AXIS 290B Power adapter (included):
Input voltage: 100-240 (50/60HZ) VAC
Input current Max 1.2A
Max Output Power 50W
Output voltage 15 VDC
Output current 3.4 A
IMPORTANT! 
Power adapter is for indoor use only!
AXIS 290B Housing:
Input voltage: 9-15 V DC 
Input current: 
Max 2.8A at 9V, 3A at 12V, 3.5A at 15V
-4F to 108F (-20°C to +42°C)  
 
Warning: The housing should 
not be exposed to many hours 
of direct sunlight as this may 
overheat and damage the 
camera beyond repair. The 
maximum temperature inside 
the housing should never 
exceed 122F (50°C). 
Specifications may change without prior notice.
INSTAL GUIDE HOUSING ENV WHITE r3.0        PART NO. 
25205
Date: July 2005         COPYRIGHT AXIS COMMUNICATIONS AB 2005