9-18        Communicate with a PanelView™ Standard Terminal
Set the Communication Path
The communication path specifies the route to the PanelView 
terminal. A communication path follows this format:
scanner_name,2,device_address
To set the path:
For more information on programming MSG instructions, see the 
Logix5000 Controller General Instructions Reference Manual
publication 1756-RM003.
Where:
Is:
scanner_name
Name of the scanner in the I/O Configuration folder of the 
controller.
device_address
Address of the device on the DeviceNet network.
1. Click the Communication tab.
2. Click the Browse button and select the 
scanner.
3. Type the rest of the path.
4. Close the dialog box.