ADC and 3 Doubler Manuale Utente

Pagina di 44
Generic Information
 
LTPH-UM-1234-01
16
April 30, 2003
 HDU-409 Lists 1, 2, and 3
A
LTERNATIVE
 D
OUBLER
 E
NCLOSURE
 
C
APACITIES
Reduce the doubler capacity by one for every two doublers that do not have 
an empty slot between them. If the application allows seven doublers, but two 
are directly adjacent to each other, then the total capacity must be reduced to 
six.
Standard T1 or LD1 repeaters can be installed in the same enclosure with 
doubler units. If this method is used, the maximum number of doublers that 
can occupy the same case with the standard repeaters must be reduced by one 
for every four T1 or LD1 repeaters (or fractions thereof) installed.
Rule one on 
, in the section titled, 
, does not apply if 
the adjacent slot is occupied by a T1 or LD1 repeater; 
however, slots adjacent to doublers should be left vacant if 
possible.