Entering Configuration Data
Chapter 3
Drive Entries
Note
For 9840 drives only:
The drive’s SCSI ID and bus status can be entered from the 
library’s operator panel if the drive has firmware version 1.24 or 
higher. Check the drive’s firmware version, by  selecting DRIVE 
INFO from the Main Menu.
Configuring a 9840 drive might involve more than setting the 
drive’s SCSI ID and bus status. For more information about 9840 
drive configuration options and instructions, refer to the 9840 
Tape Drive Service Manual.
Two entries complete the configuration options for each SCSI drive:
SCSI ID
Bus status (on or off bus)
Note
“On Bus” means that the drive is on the same SCSI bus as the 
library. “Off Bus” means that the drive is not on the same SCSI 
bus as the library.
Set the drive SCSI IDs and bus status from the drive configuration menu. You 
can enter both values for each drive at the same time:
1. At the main Configuration Menu, press an arrow button until the cursor 
underscores DRIVE CONFIG. 
2. Press 
the 
[SELECT] button.
The screen will list all installed drives, and the cursor will align with the first 
drive on the list.
An example of the format is:
00 HP LTO ID: 01
ON BUS: ON
The first two digits are the drive’s logical number (the number that the 
library has assigned the drive). The tape library sets this number during its 
automatic configuration sequence (at power-on or reset). It is an internal 
number only and is shown for information only