Full Command and Function Reference   3-63 
• 
z
low
 and z
high
 are real numbers that specify the height of the view space. 
• 
x
min
 and x
max
 are not used. 
• 
y
min
 and y
max
 are not used. 
• 
x
eye
y
eye
, and z
eye
 are are not used. 
• 
x
step
 and y
step
 are real numbers that set the number of x-coordinates versus the number of y-
coordinates plotted. 
 
The plotting parameters are specified in the reserved variable PPAR, which has this form: 
{ (x
min
y
min
)
,
(x
max
y
max
)
,
indep
,
res
,
axes
,
ptype
,
depend } 
 
For plot type FAST3D, the elements of PPAR are used as follows: 
• 
(x
min
y
min
) is not used. 
• 
(x
max
y
max
) is not used. 
• 
indep is a name specifying the independent variable. The default value of indep is X
• 
res is not used. 
• 
axes is not used. 
• 
ptype is a command name specifying the plot type. Executing the command FAST3D places 
the name FAST3D in ptype
• 
depend is a name specifying the dependent variable. The default value is Y
Access: 
…µ
FAST
3
D
 
Input/Output:  None
 
See also: 
BAR, CONIC, DIFFEQ, FUNCTION, GRIDMAP, HISTOGRAM, PARAMETRIC, 
PARSURFACE, PCONTOUR, POLAR, SCATTER, SLOPEFIELD, TRUTH, WIREFRAME, 
YSLICE 
 
FCOEF 
CAS:  
From an array of roots and multiplicities/poles, return a rational polynomial. 
 
FC? 
Type: Command 
Description: Flag Clear? Command: Tests whether the system or user flag specified by n
flag number
 is clear, and 
returns a corresponding test result: 1 (true) if the flag is clear or 0 (false) if the flag is set.  
Access: 
TEST 
LL
FC
?
 
   ( 
°is the left-shift of the Nkey). 
                      
 
L
MODES FLAG FC
?
 
  
( °is the left-shift of the Nkey). 
                       
  !&H
 FLAG FC
? 
Input/Output: 
 
Level 1/Argument 1 
 
Level 1/Item 1 
n
flag number
 
→ 
0/1 
See also: 
CF, FC?C, FS? FS?C, SF 
 
FC?C 
Type: Command 
Description: Flag Clear? Clear Command: Tests whether the system or user flag specified by n
flag number
 is clear, 
and returns a corresponding test result: 1 (true) if the flag is clear or 0 (false) if the flag is set. 
After testing, clears the flag. 
Access: 
TEST 
LL
FC
?
C
   ( 
°is the left-shift of the Nkey). 
                   
 
L
MODES FLAG FC
?
C
  
( °is the left-shift of the Nkey). 
                      
  !&H
 FLAG FC
?
C