HP 71576286 Manuale Utente

Pagina di 35
FP USER INSTRUCTIONS ENGLISH 71576286 - 07/06
Page 24 of 35
Example of straight
Example of bevel cut
Ensure a tightening on the stuffing
box housing and not on the sleeve.
SETTING OF PACKING
Follow the instructions:
a) Assemble of the packing in S.
b) Stagger by about 90° between two rings.
c)
Assemble packing after packing.
After setting the last packing ring, secure the
packing with the gland and tighten the nut by hand.
After tightening, the shaft should turn by hand as
easily as before the setting of the packing.
DIMENSIONS IN MILLIMETERS
PACKING
PUMP
TYPE
D1
D2
D3
D4
D5
L1
Lgth
50 FP
24
30
46
70
M10
48
600
8
65 FP
24
30
46
70
M10
48
600
8
80 FP
32
40
60
86
M12
63
800
10
100 FP
32
40
60
86
M12
63
800
10
122 FP
45
55
75
100
M12
45
850
10
125 FP
40
50
70
96
M12
60
1000
10
152 FP
55
70
95
135
M12
78
1100
12
202 FP
65
80
109
150
M16
91
1200
14
For arrangement of packing, see section 8.1,
Sectional drawings.
6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or cracks
of the coating found must be immediately repaired.
Failure to do this may lead to accelerated wear of
the coating during operation and corrosion of the
exposed base metal, depending on the material and
pumped liquid. Special attention must be paid to the
coating edges. Any loss of coating material is
considered to be normal wear and tear on the pump
and is not considered as warranty. Flowserve has
applied the coatings according to the supplier's
instructions but will not be held responsible for
coating wear or cracks that may develop over time.
6.3 Spare parts
6.3.1 Ordering of spares
Flowserve 
keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted:
1) Pump serial number.
2) Pump size.
3) Part name
4) Part number
5) Number of parts required.
The pump size and serial number are shown on the
pump nameplate.
To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve. Any change to
the original design specification (modification or use
of a non-standard part) will invalidate the pump’s
safety certification.