Server component identification 13 
System LED and Color 
Internal Health 
LED Color 
Status 
 
Amber 
• 
DIMM in slot X has reached single-bit correctable 
error threshold. 
• 
DIMM in slot X is in a pre-failure condition. 
• 
DIMM in slot X is an unsupported type, but valid 
memory exists in another bank. 
DIMM failure, all slots 
in one bank (Amber) 
Red 
No valid or usable memory is installed in the system. 
Overtemperature 
(Amber) 
Amber 
The Health Driver has detected a cautionary temperature 
level. 
 
Red 
The server has detected a hardware critical temperature 
level. 
Riser interlock 
(Amber) 
Red 
The PCI riser board assembly is not seated. 
Fan module (Amber) 
Amber 
A redundant fan has failed. 
Fan module (Red) 
Red 
The minimum fan requirements are not being met in one or 
more of the fan modules. One or more fans have failed or 
are missing. 
Power supply signal 
interlock (Amber) 
Red 
The power supply signal cable is not connected to the 
system board. 
 
 
Internal USB connector 
 
For more information, refer to "Internal USB functionality (on page