Diagnostics mode
61
2
Formatter diagnostics
Test
Description
REPEAT
If set to yes, the tests will run continuously until 
interrupted. In the 4550 series only
[C
ANCEL
 J
OB
]
 
will abort the test.
ON FAULT
The following will occur for each setting:
BREAK – The test will stop when a failure occurs.
PAUSE – Stops the test for a short period of time 
then resume with the remaining tests.
CONT – Continues to execute the tests even 
when a failure occurs.
ROM CRC
4500 series only. Tests the firmware ROM for 
correct functionality.
DRAM
Tests the on-board RAM and the DIMMs.
SRAM 1
Tests the SRAM inside the ASIC.
SRAM 2
Tests the SRAM physically mounted on the 
formatter.
NVRAM
CAUTION
Do not interrupt the NVRAM test. Doing so will 
cause the printer to lose all NVRAM values.
Tests the formatter NVRAM. This test takes 18 
minutes to run and should only be used when 
NVRAM values are being lost. In almost all cases, 
this test should never be run.
In the 4550 series only
[C
ANCEL
 J
OB
]
 will abort 
the test. Do not turn off the printer or corruption of 
the NVRAM could result; if the NVRAM test must 
be aborted, use the 
[C
ANCEL
 J
OB
]
 key.
EXECUTE TESTS
Runs the selected tests.