HP color laserjet 4500 Manuale Utente

Pagina di 220
EN
Overcurrent/overvoltage protection
73
3
Overcurrent/overvoltage protection
Each DC power supply circuit has an overcurrent protective function 
and overvoltage protective function. This prevents a power supply 
circuit failure by automatically interrupting the output voltage when 
anomalies such as a short develop on the loads that result in 
overcurrent flow or abnormal voltage.
Note
Protective functions remain active for two minutes after activation. 
Wait for at least 2 minutes to turn the power back on again.
If this function is activated and no DC voltage is output from the 
low-voltage power supply circuit:
1
Turn off the power switch (SW6).
2
Unplug the power cord.
3
Resolve the anomaly on the load.
4
Turn the power switch (SW6) on again.